TSL SC-11 Under monitor display system controller also called TME-SC-11
Technical Details |
Manufacturer’s Specification
|
Model SUU120-180
|
Input Voltage
|
90~264 VAC, 47~63 Hz
|
Input Current
|
1.0 A @ 230 VAC, 1.7 A @ 115 VAC
|
Output Voltage
|
See table below (plus +/-5% adjustment range on O/P 1)
|
Over Load Protection
|
110~150% of rated current (auto-recovery)
|
Over Voltage Protection
|
112~132% of output voltage (crowbar)
|
Efficiency
|
70-88% (dependent on unit)
|
Line Regulation
|
0.5% typically
|
Load Regulation
|
+/-3% typical on single output units @ 230 VAC input
|
Hold Up Time
|
16 ms @ 110 VAC input
|
Switching Frequency
|
80 kHz typical
|
Leakage Current
|
0.4mA (0.75 mA max.) @ 240 VAC input and full load
|
Isolation Voltage
|
I/P-O/P: 3 kVAC, I/P-FG: 1.5 kVAC
|
Operating Temperature
|
0 °C to +70 °C (derating by 2.5% / C above 50 C)
|
Safety Standards
|
UL60950-1, TUV EN60950-1
|
EMC Standard
|
EN55022 Class B, EN55024, EN61000-3-2, 3
|
MTBF
|
>100 khrs (MIL-HDBK-217F) @ 25 C
|
Weight
|
Approx 0.5 kg each
|
Dimensions
|
127(L) x 81.4(W) x 39.2(H)
|
|