Glensound GS-OC26 Commentary Control Unit For GS-OC24 Commentators unit
-
$999.00
- Brand: Glensound
- Model Number: GS-OC26
- Product Code: BS18950
- Availability: In Stock

This system connects the GS-OC26 1U base station to the
GS-OC24 Commentators Box via a standard coaxial cable. All communications and
program lines including the power for the commentator's box are carried by
this connection.
GS-OC26 Commentary Control Unit
Inputs
There is a front panel microphone for the engineer. International sound comes
in via a rear panel ‘D’ connector.
Outputs/Talkback
An additional talkback circuit is available only to the engineer on the
GS-OC26. All rear panel audio input/output are on ‘D’ type connectors. There
are direct outputs of the 3 commentator inputs plus a mixed program output of
all commentator inputs. A single common talkback output, plus the engineer's
talkback output is available. The rear panel also features 2 outputs for local
monitor speakers. The front panel has an output mixer to mix levels between the
3 commentary unit inputs, and the international sound. In addition, the front
panel features two line idents, one for the program output and one for the
co-ordination talkback circuit.
Monitoring
The engineer can monitor all audio via a front panel 6.35mm jack socket for headphones
or via the rear panel monitor outputs for loudspeakers (audio on these is
identical). The two channels each have a level pot for independent channel
adjustment. The engineer can monitor all inputs and outputs via front panel
push buttons which are pre-defined across the left or right monitoring
channels. There is a 14 segment LED PPM meter.
Power
The GS-OC26 has an internal switch-mode power supply 110-240v.
Link
The system links via coaxial cable. Using suitable cable, the GS-OC24 can be up
500m away from the GS-OC26. The link carries bi-directional audio, data, and
remote power for the GS-OC24 via its cable connection, omitting the need for
local power. Multiple GS-OC26s can also be linked for sharing of monitoring
where one engineer can easily control multiple systems whilst being connected
to only one.
Extras
There is a call function enabling the two main commentators, the engineer, and
the co-ordinator to call each other.