Bryant broadcast Mains Distribution Unit 10 ways










- Stock: 1
- Code: BS17495
- Model: CMU 110B
CMU
214PThese dual input, 14 outlet Changeover Mains Distribution Units replace
the CMU 110B/D and CMS 110B/D 10 outlet versions.
Designed for installations
that have two coherent mains supplies, it allows
seamless switching between the
two supplies, keeping mission critical equipment alive
during loss of one supply.
Particularly useful in installations where some pieces
of equipment do not have
their own inbuilt redundant power supplies.
The custom micro-controller monitors the two incoming
inputs and if either input
fails, an alarm will sound to alert the engineer.
Assuming it is the preferred supply
that has failed, the unit will switch to the other
supply within approximately 20mS.
When the preferred supply reappears, the unit waits for
10 seconds to check that it
is stable and then initiates the change back process.
This process monitors the
relative phase of the two supplies and only allows
switch back once the two supplies
are in phase. Each input has its own bi-colour LED to
display its status. For
installations where there isn't a preferred supply, the
unit can be configured with
neither supply being the preferred supply, when the
active supply will remain
selected until it disappears or is manually changed over.
Each outlet is individually fused and has a bi-colour
LED indicator to display its
status. As this unit is based on our sequential mains
unit, when it is first powered,
the outlets will turn on sequentially. As the relays
switch each outlet on, it's
associated LED will turn Green. If for any reason the
fuse blows, or the relay fails to
switch, then the LED will turn Red to indicate a fault
condition.
All IEC outlet connectors are 10 Amp rated, cables being
secured to the integral tiebar. The inputs are 20 Amp Neutrik powerCON and mating
connectors are supplied.
The remote start function of the SMR 110B has been made
available in the CMU
214P MDU by linking two pins on the rear panel mounted D
connector.
The CMS 214P has a serial connection on the rear panel
allowing remote control and
monitoring from third party building management systems,
plus comprehensive
programming of the internal sequences.
These units are fitted with a 'Power On' neon indicator.
Please Note: These units are designed for EU mains or
similar, 230VAC +/-10% with
neutral and earth nominally at the same potential. They
are not for use on lower
mains voltages, for example 100-120VAC, although custom
builds are possible for
larger orders. The units should never be used on rare
'balanced' mains where live
and neutral are centred on earth, L/N measuring similar
voltages to earth. Balanced
mains requires fusing in both live and neutral
distribution.
Technical Details
CMU 214PThese dual input, 14 outlet Changeover Mains Distribution Units replace the CMU 110B/D and CMS 110B/D 10 outlet versions. Designed for installations that have two coherent mains supplies, it allows seamless switching between the two supplies, keeping mission critical equipment alive during loss of one supply.
Particularly useful in installations where some pieces of equipment do not have their own inbuilt redundant power supplies.
The custom micro-controller monitors the two incoming inputs and if either input fails, an alarm will sound to alert the engineer. Assuming it is the preferred supply that has failed, the unit will switch to the other supply within approximately 20mS.
When the preferred supply reappears, the unit waits for 10 seconds to check that it is stable and then initiates the change back process. This process monitors the relative phase of the two supplies and only allows switch back once the two supplies are in phase. Each input has its own bi-colour LED to display its status. For installations where there isn't a preferred supply, the unit can be configured with neither supply being the preferred supply, when the active supply will remain
selected until it disappears or is manually changed over.
Each outlet is individually fused and has a bi-colour LED indicator to display its
status. As this unit is based on our sequential mains unit, when it is first powered,
the outlets will turn on sequentially. As the relays switch each outlet on, it's
associated LED will turn Green. If for any reason the fuse blows, or the relay fails to
switch, then the LED will turn Red to indicate a fault condition.
All IEC outlet connectors are 10 Amp rated, cables being secured to the integral tiebar. The inputs are 20 Amp Neutrik powerCON and mating connectors are supplied.
The remote start function of the SMR 110B has been made available in the CMU
214P MDU by linking two pins on the rear panel mounted D connector.
The CMS 214P has a serial connection on the rear panel allowing remote control and
monitoring from third party building management systems, plus comprehensive
programming of the internal sequences.
These units are fitted with a 'Power On' neon indicator.
Please Note: These units are designed for EU mains or similar, 230VAC +/-10% with
neutral and earth nominally at the same potential. They are not for use on lower
mains voltages, for example 100-120VAC, although custom builds are possible for
larger orders. The units should never be used on rare 'balanced' mains where live
and neutral are centred on earth, L/N measuring similar voltages to earth. Balanced
mains requires fusing in both live and neutral distribution.